The XCP is a low-cost,
high-duration multi-place oxygen system. With the A3 and Oxymizer cannula
each person will use at most 1.0 liter/min. at 18,000 ft. This makes it
easy to calculate your cylinder life time. Example: If you have 415 liters
and four persons and are to cruise at 18,000 ft., you would divide 415
by 4 which equals 103 min. per person. The flow rate at 18,000 ft. is
typically only 3/4 (0.750) liter/ minute with the Oxymizer cannula.
However, 1.0 liter/min. isused
as a worst-case scenario and for calculation conven- ience. The XCP delivery
system consists of: (1) XCP quad- port regulator with self-sealing outlets,
(4) XCP face masks for use w/ the A4 flowmeter or nasal congestion, (4)
Nelson A3 flowmeter/regulators with 3 feet of high quality tubing w/ CPC
connectors and 4 Oxymizer® type "M" nasal cannulas, (1) Oxygen cylinder
(AL-415 or AL-682), (1)TuffPack padded fabric carry/strapping case for
cylinder and equipment. XCP system comes w/ the A3 flowmeter/regulator.
It has an alti- tude/flow scale calibrated for the unique Oxymizer oxygen-
conserving cannula. The scale is marked in 2,000 ft. incre- ments for
VFR flight levels up to 18,000 ft. You can operate the XCP in IFR flight
levels with the optional A4 flowmeter/ regulator and associated F1 face
masks. This will, use much more oxygen. All systems are shipped empty. |